Series 5400
|
Series 5500
|
Series 5600
|
|
Capacity
|
1-Gallon
|
2-Gallons
|
5-Gallons
|
|
Internal Dimensions
|
5" ID X 12" IL
|
6.5" ID X 14" IL
|
10" ID X 15" IL
|
|
Design Pressure Options
|
2,000 psi
|
2,000 psi
|
1,000 psi
|
|
|
5,000 psi
|
5,000 psi
|
3,000 psi
|
|
Design Temperature
|
350oC |
350oC |
350oC |
|
Motor Horsepower
|
1/2 Hp
|
1/2 Hp
|
1/2 Hp
|
|
Impellor Speed Range (Rpm)
|
150-1500
|
100-1000
|
70-700
|

|
|
Motor Type
|
Electric, Totally-Enclosed Fan-Cooled (Explosion-Proof Optional)
|
|
Impellor Type
|
(2) Pitched-Blade Turbines
|
|
Mixer type
|
Leak-free, contamination-free, top entering MAGNETIC DRIVE.
|
|
Heater type
|
Electric Band Heaters
|
|
Temperature control
|
PID controller with digital readout
|
|
Head connections
|
1 Gas Inlet With Valve-Can Be Fitted With A Dip Tube
1 Liquid Sample Valve With Dip Tube
1 Thermowell
2 Spare Openings
|
|
*Body flange connections
|
1 Pressure Gauge
1 Rupture Disc
1 Vent Valve
|
|
*Note:
|
Body Flange Connections Would Be Located In The Head For Hydraulic Stand Options.
|
|
Stand Options
|
Frame-style Floor Stand or Hydraulic Floor Stand
|
REQUEST QUOTATION

|